通用banner

What are the humidification methods for precision air conditioners?

2020-04-13 16:42:24
Times

Many people have seen precision air conditioning , so do you know whatare the humidification methodsfor precision air conditioning ?

1. Electrode

  The electrode humidifier controls the water level of the humidification tank and the size of the electrical conductivity to control the steam output. Following the continuous output of steam volume, the water level of the electrode tank drops accordingly, and the computer controller will open the water inlet valve again to replenish the electrode tank with fresh water to meet the humidification requirement.


2. Infrared

  Infrared humidifiers are used in places with constant temperature and humidity, but also in highly clean places. When the humidity of the air-conditioned room is lower than the set humidity, it will output a humidification signal through the computer and use high-intensity quartz lamp power supply to connect.


Three, pure?

  The pure humidifier uses the dynamic balance principle to control the relative humidity of the environment between 45% and 65% RH. When the indoor relative humidity is higher than 50% RH, the humidifier will automatically reduce the humidification amount, so that the environment can maintain constant humidity.


4. Air Conditioning Monitoring

  The pan-geographical precision air conditioner computer room monitoring system consists of front-end equipment, user terminal / service terminal APP, and users can log in through the user terminal APP / PC to view the operation status and related parameters of the precision air conditioning in real time. When the temperature and humidity return air, the supply air exceeds the limit and other faults, it can receive the alarm information synchronously and respond quickly to eliminate the fault.


5. Ultrasonic 

      Ultrasonic humidifier is to disperse water mist into the air through wind-driven equipment to meet the needs of evenly humidified air. It has a long service life and has the advantages of automatic humidity balance and automatic protection without water.


6. Electrode boiler

  Electrode boiler humidifier is composed of electrode boiler, steam spray pipe, water inlet solenoid valve, drain solenoid valve and water level controller. When the humidity in the air-conditioned room is lower than the set humidity, the humidification signal is output through the computer, the power is turned on, the solenoid valve is opened, and the water is filled to the level of the sensor.


精密空调

 Precision air conditioning , precision air conditioning in computer room, precision distribution cabinet in computer room