Many people have heard of precision air conditioners , so do you understand why professional precision air conditioners are used in computer rooms?
When comfortable air conditioners were used in the early computer rooms, there were often unstable operation of the equipment in the room due to improper control of ambient temperature and humidity parameters, data transmission was disturbed, static electricity and other problems, and fluctuations in temperature or humidity also caused some problems. The standard comfort air conditioner is not designed to handle the heat load concentration and composition of the data room, nor to provide the precise temperature and humidity setpoints required for these applications. The design of the precision air-conditioning system is for precise temperature and humidity control. The precision air-conditioning system has high reliability, guarantees the continuous operation of the system throughout the year, and has maintainability, assembly flexibility and redundancy, which can ensure the normal air-conditioning in the data room for four seasons. run. Air-cooled D series small machine room precision air conditioner machine room should use precision air conditioner. Normal comfort air conditioner should not be installed, because the common air conditioner mainly only provides suitable temperature for users, but the equipment in the data center of the machine room includes servers, switches, cabinets These devices, such as UPS and UPS uninterruptible power supply, will radiate heat into the computer room by means of heat transfer, convection, and radiation. These heats only form an increase in the temperature in the computer room.
Precision air-conditioning in the computer room throughout the year The precision air-conditioning in the computer room is designed for the computer room. The uninterrupted work and operation of the computer room requires its internal equipment to run uninterrupted. The precision air-conditioning in the computer room can do this. Work uninterrupted days, provide cooling and constant temperature and humidity protection for the data center of the computer room, and escort the normal operation of the computer room. The high sensible heat ratio of the precision air conditioner in the equipment room refers to the ratio of sensible cooling capacity to total cooling capacity. The total cooling capacity of the air conditioner is the sum of the sensible cooling capacity and the latent cooling capacity. The sensible cooling is used to lower the temperature, and the latent cooling is used to dehumidify. The heat in the data center of the computer room is mainly sensible heat, and the sensible heat of the precision air conditioner in the computer room is relatively high, usually above 0.9. Large air volume and small difference are the essential difference between precision air conditioning and ordinary air conditioning. Choosing a large air volume can make the temperature of the outlet air not too low, and increase the number of air changes in the equipment room, which is beneficial to the reliability and stability of the equipment in the equipment room.
Computer room precision air conditioning , computer room precision power distribution cabinet , computer room micro-module