● Adopting digital control design, and the control system is more reliable
● High power density design, capacity of single power module is 6KVA/ 10KVA/ 15KVA/ 20KVA/ 25KVA/ 30KVA/ 40KVA, the height of all these modules is 3U.The power of system ranged from 6KVA to 520KVA corresponds to the number of parallel power modules from 1 to 13
● Redundant control system, each power module is equipped independent control system, and control itself independently according to the sharing message, and the fault module separates from the system automatically
● Support parallel expansion for cabinet, and parallel expansion is up to 4 cabinets.
● Voltage of batteries can be configured flexibly, 1 input 1 output/ 3 input 1 output ±96Vdc/ ±108Vdc/ ±120Vdc(16/18/20PCS)selectable; 3 input 3 output±216Vdc/±228Vdc/±240Vdc (32/34/ 36/38/40PCS) selectable
● Intelligent charging mode, Charging current can be configured , there are 3 charging mode which are constant current mode、constant voltage mode、floating charging mode, and the charging mode can be transfer smoothly.
MODEL | HPM3325-250KVA | HPM3330-90KVA | HPM3330-150KVA | HPM3330-300KVA | HPM3340-200KVA | HPM3340-320KVA | HPM3340-400KVA | HPM3340-520KVA | HPM3340-800KVA | HPM3340-1280KVA | HPM3340-1560KVA | |
Capacity (VA/Watts) | UPS cabinet | 250k / 225k | 90k / 81k | 150k / 135k | 300k / 270k | 200k/180k | 320k/288k | 400k / 360k | 520k / 468k | 800k / 720k | 1280k / 1152k | 1560k / 1404k |
HPM module | 25k / 22.5k | 25k / 22.5k, 30k / 27k | 40k / 36k | |||||||||
INPUT | ||||||||||||
Nominal voltage | 380/400/415Vac, (3Ph+N+PE) | |||||||||||
Operating voltage range | 208~478Vac for half load; 305~478Va c for full load | |||||||||||
Operating frequency range | 40~70Hz | |||||||||||
Power factor | ≥0.99 | |||||||||||
Harmonic distortion (THDi) | 3%(100% non-linear load) | |||||||||||
Bypass voltage range | 380Vac Max.voltage: +25%(optional +10%,+15%,+20% ) 400Vac Max.voltage: +20% (optional +10%,+15%) 415Vac Max.voltage: +15% (optional +10%) Min.voltage: -45% (optional -20%,-30%) | |||||||||||
Bypass frequency range | Frequency synchronize tracing range:±10% | |||||||||||
Generator access | Support | |||||||||||
OUTPUT | ||||||||||||
Rated voltage | 380/400/415Vac(3Ph+N+PE) | |||||||||||
Power factor | 0.9 | |||||||||||
Voltage regulation | ±1% | |||||||||||
Frequency | Line mode | ±1%/±2%/±4%/±5%/±10% of the rated frequency(optional) | ||||||||||
Bat. mode | (50/60±0.1%)Hz | |||||||||||
Crest factor | 3:1 | |||||||||||
Harmonic distortion (THDv) | ≤2% with linear load ≤5% with non-linear load | |||||||||||
Efficiency | 95.00% | |||||||||||
BATTERY | ||||||||||||
Battery voltage | ±192/±204/±216/±228/±240Vdc; Battery quantity(optional) | |||||||||||
Charging current(A) | UPS cabinet | 60A (Max.) | 30A (Max.) | 50A (Max.) | 100A (Max.) | 50A (Max.) | 80A (Max.) | 100A (Max.) | 130A (Max.) | 200A (Max.) | 320A (Max.) | 390A (Max.) |
HPM module | 6A (Max.) | 25kVA:6A (Max.) / 30kVA:10A (Max.) | 10A (Max.) | |||||||||
Backup time | Depends on the capacity of external batteries | |||||||||||
SYSTEM FEATURES | ||||||||||||
Transfer time | Utility to battery:0ms; Utility to bypass:0ms | |||||||||||
Overload | Line mode | Load≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% turn to bypass mode immediately | ||||||||||
Bat. mode | Load≤110%: last 10min,≤125%: last 1min,≤150%: last 1S,≥150% shut down UPS immediately | Load≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% shut down UPS immediately | ||||||||||
Bypass mode | Breaker (25kVA:40A) | Breaker ( 25kVA:40A / 30kVA:60A) | 40kVA:95A | |||||||||
Short circuit | Hold whole system | |||||||||||
Noise suppression | Complies with EN62040-2 | |||||||||||
Communication interface | UPS cabinet : RS232, RS485, Dry contact, Intelligent slot x 2(SNMP card,Relay card optional); HPM series UPS module: RS232 | |||||||||||
ENVIRONMENT | ||||||||||||
Operating temperature | 0~40℃ | |||||||||||
Storage temperature | -25~55℃ | |||||||||||
Humidity range | 0~95% (Non-condensing) | |||||||||||
Altitude | <1500m. When >1500m, derating power for use | |||||||||||
Noise level | <70dB | <65dB | <70dB | <73dB | ||||||||
PHYSICAL | ||||||||||||
Dimension D×W×H (mm) | UPS cabinet | 1100×600×2000 | 840×600×1400 | 1100×600×2000 | 850×600×1600 | 850×600×2000 | 850×1200×2000 | 850×2000×2000 | 850×3400×2000 | 4800×850×2000 | ||
HPM module | 443x580x131 (3U) | |||||||||||
Net weight (kg) | UPS cabinet | 290 | 158 | 170 | 307 | 251 | 320 | 540 | 980 | 1400 | 2800 | |
HPM module | 32 | 25kVA/32; 30kVA/33.5 | 36 | |||||||||
STANDARDS | ||||||||||||
Safety | IEC/EN62040-1,IEC/EN60950-1 | |||||||||||
EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |